{"product_id":"pingerelee-3f-n-faasi-kadu-jarjestus-1co-viivis-0-1-10s-3x400v-230-hrn-55n-elko","title":"Pingerelee 3F+N, faasi kadu\/järjestus, 1CO, viivis 0,1-10s, 3x400V\/230, HRN-55N, Elko","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\" data-end=\"431\" data-start=\"71\"\u003eELKO EP \u003cstrong data-end=\"90\" data-start=\"79\"\u003eHRN-55N\u003c\/strong\u003e on DIN-liistule paigaldatav \u003cstrong data-end=\"159\" data-start=\"119\"\u003e3-faasilise võrgu pingekontrollrelee\u003c\/strong\u003e, mis jälgib faaside olemasolu, õiget faasijärjestust ning ala- ja ülepinget. HRN-55N versioon jälgib lisaks ka \u003cstrong data-end=\"297\" data-start=\"271\"\u003eneutraaljuhi katkemist\u003c\/strong\u003e, mistõttu sobib see 3-faasiliste 400\/230 V elektripaigaldiste kaitse- ja juhtimislahendustesse.\u003c\/p\u003e\r\n\r\n\u003cp data-end=\"620\" data-start=\"433\"\u003eReleed saab kasutada näiteks mootorite, pumpade, kompressorite ja muude 3-faasiliste seadmete kaitsmiseks olukordades, kus vale faasijärjestus või faasi kadumine võib seadmeid kahjustada.\u003c\/p\u003e\r\n\r\n\u003ch2 data-end=\"642\" data-section-id=\"1e8gqrv\" data-start=\"622\"\u003eTehnilised andmed\u003c\/h2\u003e\r\n\r\n\u003cul data-end=\"1448\" data-start=\"644\"\u003e\r\n\t\u003cli data-end=\"665\" data-section-id=\"fpecf5\" data-start=\"644\"\u003eTootja: \u003cstrong data-end=\"665\" data-start=\"654\"\u003eELKO EP\u003c\/strong\u003e\n\u003c\/li\u003e\r\n\t\u003cli data-end=\"686\" data-section-id=\"1tc7e8\" data-start=\"666\"\u003eMudel: \u003cstrong data-end=\"686\" data-start=\"675\"\u003eHRN-55N\u003c\/strong\u003e\n\u003c\/li\u003e\r\n\t\u003cli data-end=\"710\" data-section-id=\"yph5py\" data-start=\"687\"\u003eTootja kood: \u003cstrong data-end=\"710\" data-start=\"702\"\u003e7513\u003c\/strong\u003e\n\u003c\/li\u003e\r\n\t\u003cli data-end=\"735\" data-section-id=\"lilytq\" data-start=\"711\"\u003eEAN: \u003cstrong data-end=\"735\" data-start=\"718\"\u003e8595188137232\u003c\/strong\u003e\n\u003c\/li\u003e\r\n\t\u003cli data-end=\"763\" data-section-id=\"k8c4pt\" data-start=\"736\"\u003eVõrk: \u003cstrong data-end=\"763\" data-start=\"744\"\u003e3-faasiline + N\u003c\/strong\u003e\n\u003c\/li\u003e\r\n\t\u003cli data-end=\"807\" data-section-id=\"1kqpma8\" data-start=\"764\"\u003eNimipinge: \u003cstrong data-end=\"807\" data-start=\"777\"\u003e3 × 400\/230 V AC, 50–60 Hz\u003c\/strong\u003e\n\u003c\/li\u003e\r\n\t\u003cli data-end=\"860\" data-section-id=\"1psufrz\" data-start=\"808\"\u003eJälgitav faas–N pingevahemik: \u003cstrong data-end=\"860\" data-start=\"840\"\u003e3 × 172–287 V AC\u003c\/strong\u003e\n\u003c\/li\u003e\r\n\t\u003cli data-end=\"901\" data-section-id=\"148x9zk\" data-start=\"861\"\u003eAlapinge piir: \u003cstrong data-end=\"901\" data-start=\"878\"\u003e75% Un, fikseeritud\u003c\/strong\u003e\n\u003c\/li\u003e\r\n\t\u003cli data-end=\"943\" data-section-id=\"d5hwe5\" data-start=\"902\"\u003eÜlepinge piir: \u003cstrong data-end=\"943\" data-start=\"919\"\u003e125% Un, fikseeritud\u003c\/strong\u003e\n\u003c\/li\u003e\r\n\t\u003cli data-end=\"980\" data-section-id=\"19tatx6\" data-start=\"944\"\u003eFaasikatkestuse jälgimine: \u003cstrong data-end=\"980\" data-start=\"973\"\u003ejah\u003c\/strong\u003e\n\u003c\/li\u003e\r\n\t\u003cli data-end=\"1017\" data-section-id=\"tytd89\" data-start=\"981\"\u003eFaasijärjestuse jälgimine: \u003cstrong data-end=\"1017\" data-start=\"1010\"\u003ejah\u003c\/strong\u003e\n\u003c\/li\u003e\r\n\t\u003cli data-end=\"1061\" data-section-id=\"blamnu\" data-start=\"1018\"\u003eNeutraaljuhi katkemise jälgimine: \u003cstrong data-end=\"1061\" data-start=\"1054\"\u003ejah\u003c\/strong\u003e\n\u003c\/li\u003e\r\n\t\u003cli data-end=\"1107\" data-section-id=\"19cu1xq\" data-start=\"1062\"\u003eVäljund: \u003cstrong data-end=\"1107\" data-start=\"1073\"\u003e1 × ümberlülituskontakt (SPDT)\u003c\/strong\u003e\n\u003c\/li\u003e\r\n\t\u003cli data-end=\"1147\" data-section-id=\"1pwja6l\" data-start=\"1108\"\u003eKontakti koormus: \u003cstrong data-end=\"1147\" data-start=\"1128\"\u003e8 A \/ 250 V AC1\u003c\/strong\u003e\n\u003c\/li\u003e\r\n\t\u003cli data-end=\"1185\" data-section-id=\"l24fce\" data-start=\"1148\"\u003eFikseeritud viivitus T1: \u003cstrong data-end=\"1185\" data-start=\"1175\"\u003e500 ms\u003c\/strong\u003e\n\u003c\/li\u003e\r\n\t\u003cli data-end=\"1226\" data-section-id=\"1appgcy\" data-start=\"1186\"\u003eReguleeritav viivitus T2: \u003cstrong data-end=\"1226\" data-start=\"1214\"\u003e0,1–10 s\u003c\/strong\u003e\n\u003c\/li\u003e\r\n\t\u003cli data-end=\"1259\" data-section-id=\"ycu630\" data-start=\"1227\"\u003eVeateate indikatsioon: \u003cstrong data-end=\"1259\" data-start=\"1252\"\u003eLED\u003c\/strong\u003e\n\u003c\/li\u003e\r\n\t\u003cli data-end=\"1295\" data-section-id=\"1q27o2h\" data-start=\"1260\"\u003ePaigaldus: \u003cstrong data-end=\"1295\" data-start=\"1273\"\u003eDIN-liist EN 60715\u003c\/strong\u003e\n\u003c\/li\u003e\r\n\t\u003cli data-end=\"1327\" data-section-id=\"18ae3ky\" data-start=\"1296\"\u003eLaius: \u003cstrong data-end=\"1327\" data-start=\"1305\"\u003e1 moodul \/ 17,6 mm\u003c\/strong\u003e\n\u003c\/li\u003e\r\n\t\u003cli data-end=\"1360\" data-section-id=\"5l2yq8\" data-start=\"1328\"\u003eMõõtmed: \u003cstrong data-end=\"1360\" data-start=\"1339\"\u003e90 × 17,6 × 64 mm\u003c\/strong\u003e\n\u003c\/li\u003e\r\n\t\u003cli data-end=\"1377\" data-section-id=\"1s6361j\" data-start=\"1361\"\u003eKaal: \u003cstrong data-end=\"1377\" data-start=\"1369\"\u003e63 g\u003c\/strong\u003e\n\u003c\/li\u003e\r\n\t\u003cli data-end=\"1448\" data-section-id=\"kjvbk8\" data-start=\"1378\"\u003eTöötemperatuur: \u003cstrong data-end=\"1410\" data-start=\"1396\"\u003e–20…+55 °C\u003c\/strong\u003e\n\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch2 data-end=\"1477\" data-section-id=\"c2sh0\" data-start=\"1450\"\u003eMida HRN-55N kontrollib?\u003c\/h2\u003e\r\n\r\n\u003cp data-end=\"1770\" data-start=\"1479\"\u003eRelee jälgib pidevalt 3-faasilise võrgu seisukorda. Kui \u003cstrong data-end=\"1624\" data-start=\"1535\"\u003efaas kaob, faasijärjestus on vale, neutraal katkeb või pinge väljub lubatud piiridest\u003c\/strong\u003e, läheb relee veaseisundisse ning väljundkontakt lülitub välja. Veaseisundist annab märku ka LED-indikaator.\u003c\/p\u003e\r\n\r\n\u003cp data-end=\"1893\" data-start=\"1772\"\u003eReguleeritav \u003cstrong data-end=\"1812\" data-start=\"1785\"\u003e0,1–10 sekundi viivitus\u003c\/strong\u003e aitab vältida tarbetut väljalülitamist väga lühiajaliste pingekõikumiste korral.\u003c\/p\u003e\r\n\r\n\u003ch2 data-end=\"1911\" data-section-id=\"533qnu\" data-start=\"1895\"\u003eSobib näiteks\u003c\/h2\u003e\r\n\r\n\u003cul data-end=\"2185\" data-start=\"1913\"\u003e\r\n\t\u003cli data-end=\"1958\" data-section-id=\"12xsq66\" data-start=\"1913\"\u003e3-faasiliste elektripaigaldiste jälgimiseks\u003c\/li\u003e\r\n\t\u003cli data-end=\"1994\" data-section-id=\"5btc8\" data-start=\"1959\"\u003eelektrimootorite kaitseahelatesse\u003c\/li\u003e\r\n\t\u003cli data-end=\"2032\" data-section-id=\"1993hrv\" data-start=\"1995\"\u003epumpade ja kompressorite juhtimisse\u003c\/li\u003e\r\n\t\u003cli data-end=\"2069\" data-section-id=\"1tc1wsb\" data-start=\"2033\"\u003eventilatsiooni- ja kütteseadmetele\u003c\/li\u003e\r\n\t\u003cli data-end=\"2102\" data-section-id=\"e766zr\" data-start=\"2070\"\u003etööstusseadmete juhtkilpidesse\u003c\/li\u003e\r\n\t\u003cli data-end=\"2136\" data-section-id=\"mnvgrn\" data-start=\"2103\"\u003efaasijärjestuse kontrollimiseks\u003c\/li\u003e\r\n\t\u003cli data-end=\"2185\" data-section-id=\"hqhd64\" data-start=\"2137\"\u003efaasi või neutraaljuhi katkemise tuvastamiseks\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003cp data-end=\"2403\" data-start=\"2187\"\u003e\u003cstrong data-end=\"2208\" data-start=\"2187\"\u003eOluline erinevus:\u003c\/strong\u003e HRN-55N on \u003cstrong data-end=\"2257\" data-start=\"2220\"\u003eneutraaljuhi jälgimisega versioon\u003c\/strong\u003e. Tavaline HRN-55 jälgib kolme faasi, kuid HRN-55N on ette nähtud \u003cstrong data-end=\"2342\" data-start=\"2323\"\u003eL1, L2, L3 ja N\u003c\/strong\u003e ühendusega süsteemile.\u003c\/p\u003e\r\n\r\n\u003ch2 data-end=\"2432\" data-section-id=\"ctrhuz\" data-start=\"2405\"\u003eSoovitame juurde vaadata\u003c\/h2\u003e\r\n\r\n\u003cp data-end=\"2584\" data-start=\"2434\"\u003ePingekontrollrelee juurde sobivad \u003cstrong data-end=\"2583\" data-start=\"2468\"\u003ekontaktorid, DIN-liistu automaatkaitselülitid, juhtkilbid, signaallambid ja muud juhtimis- ning kaitseaparaadid\u003c\/strong\u003e.\u003c\/p\u003e\r\n\r\n\u003cp data-end=\"2724\" data-is-last-node=\"\" data-is-only-node=\"\" data-start=\"2586\"\u003eEi ole kindel, kas \u003cstrong data-end=\"2624\" data-start=\"2605\"\u003eELKO EP HRN-55N\u003c\/strong\u003e sobib sinu 3-faasilise süsteemi kaitseks? Kirjuta või helista meile – aitame valida õige lahenduse.\u003c\/p\u003e\r\n","brand":"ELKO","offers":[{"title":"Default Title","offer_id":54993958895959,"sku":"HRN-55N","price":43.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0932\/9796\/7447\/files\/9562_hrn-55n-big.png?v=1789196027","url":"https:\/\/www.elektripood.ee\/products\/pingerelee-3f-n-faasi-kadu-jarjestus-1co-viivis-0-1-10s-3x400v-230-hrn-55n-elko","provider":"Elektripood.ee","version":"1.0","type":"link"}