{"title":"Fire-resistant cables","description":"\u003cp data-start=\"25\" data-end=\"351\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cstrong data-start=\"25\" data-end=\"48\"\u003eFire-resistant cables\u003c\/strong\u003e are specialized electrical cables that maintain power supply and signal transmission even at high temperatures in the event of a fire. They are used in buildings and facilities where electrical systems must continue to operate during a fire to ensure the safe evacuation of people and the functioning of fire safety systems.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"353\" data-end=\"702\"\u003eIn our selection, you will find high-quality fire-resistant cables for various installation needs. They are suitable for use in fire alarm, emergency lighting, smoke extraction, sprinkler, and other safety systems. Fire-resistant cables meet high quality and safety standards and are suitable for residential, commercial, and industrial buildings.\u003c\/p\u003e\n\u003cp data-start=\"704\" data-end=\"815\"\u003eChoose reliable fire-resistant cables that ensure system reliability even under the most demanding conditions.\u003c\/p\u003e","products":[{"product_id":"kaabel-tulekindel-5x1-5-oranz","title":"Cable fire-resistant 5x1.5 mm² orange","description":"\u003cp data-end=\"344\" data-start=\"71\"\u003ePrysmian's fire-resistant FIRETUF FRHF cable is suitable for electrical installations where cable reliability must be ensured even during a fire. It is used, for example, as a power or connection cable for emergency lighting, fire alarm, smoke extraction, control, and safety systems.\u003c\/p\u003e\n\n\u003cp data-end=\"566\" data-start=\"346\"\u003eThe 5G1.5 mm² cable is suitable for fixed installations requiring a five-core fire-resistant cable with a protective conductor. The 90-minute fire resistance helps ensure the continued operation of essential systems for the specified duration in the event of a fire.\u003c\/p\u003e\n\n\u003cp data-end=\"1072\" data-start=\"568\"\u003e\u003cstrong data-end=\"589\" data-start=\"568\"\u003eTechnical specifications\u003c\/strong\u003e\u003cbr data-end=\"592\" data-start=\"589\"\u003e\nEAN: 6410004203729\u003cbr data-end=\"613\" data-start=\"610\"\u003e\nManufacturer: Prysmian\u003cbr data-end=\"632\" data-start=\"629\"\u003e\nProduct code: 1250817\u003cbr data-end=\"653\" data-start=\"650\"\u003e\nSupplier product code: 20098041\u003cbr data-end=\"683\" data-start=\"680\"\u003e\nCable type: FIRETUF FRHF\u003cbr data-end=\"711\" data-start=\"708\"\u003e\nProduct type: fire-resistant cable \/ halogen-free fire-resistant cable\u003cbr data-end=\"776\" data-start=\"773\"\u003e\nCable size: 5G1.5 mm²\u003cbr data-end=\"801\" data-start=\"798\"\u003e\nNumber of conductors: 5\u003cbr data-end=\"819\" data-start=\"816\"\u003e\nConductor cross-section: 1.5 mm²\u003cbr data-end=\"845\" data-start=\"842\"\u003e\nProtective conductor: yes\u003cbr data-end=\"863\" data-start=\"860\"\u003e\nVoltage: 500 V\u003cbr data-end=\"878\" data-start=\"875\"\u003e\nFire resistance: 90 min\u003cbr data-end=\"900\" data-start=\"897\"\u003e\nMinimum purchase quantity: 1 m\u003cbr data-end=\"928\" data-start=\"925\"\u003e\nPackage quantity: 1\/500\u003cbr data-end=\"951\" data-start=\"948\"\u003e\nApplication: emergency lighting, fire alarm, smoke extraction, control and safety systems, and fixed installations\u003c\/p\u003e\n\n\u003cp data-end=\"1391\" data-start=\"1074\"\u003e\u003cstrong data-end=\"1091\" data-start=\"1074\"\u003eSuitable for, for example\u003c\/strong\u003e\u003cbr data-end=\"1094\" data-start=\"1091\"\u003e\nconnecting emergency lighting;\u003cbr data-end=\"1126\" data-start=\"1123\"\u003e\ninstalling fire alarms and safety systems;\u003cbr data-end=\"1190\" data-start=\"1187\"\u003e\nsmoke extraction and control systems;\u003cbr data-end=\"1234\" data-start=\"1231\"\u003e\nbuilding fire safety installations;\u003cbr data-end=\"1270\" data-start=\"1267\"\u003e\nfixed installations requiring fire-resistant cable;\u003cbr data-end=\"1325\" data-start=\"1322\"\u003e\nlocations requiring a 5-core 1.5 mm² fire-resistant cable.\u003c\/p\u003e\n\n\u003cp data-end=\"1529\" data-start=\"1393\"\u003eWe recommend also looking at: fire-resistant cable clips, junction boxes, fire detectors, emergency lights, cable strippers, and installation accessories.\u003c\/p\u003e\n\n\u003cp data-end=\"1636\" data-start=\"1531\"\u003eNot sure if this fire-resistant cable is suitable? Write or call us — we will help you choose the right solution.\u003c\/p\u003e\n","brand":"PRYSMIAN","offers":[{"title":"Default Title","offer_id":51706677494103,"sku":"KAAB14","price":5.11,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0932\/9796\/7447\/files\/9213_Kaabel-tulekindel-5x15-mm-oranz.jpg?v=1783527155"},{"product_id":"kaabel-tulekindel-3x2-5-oranz","title":"Fire-resistant cable 3G2.5 mm² orange","description":"\u003cp data-end=\"344\" data-start=\"71\"\u003ePrysmian's fire-resistant FIRETUF FRHF cable is suitable for electrical installations where cable reliability must be ensured even in the event of a fire. It is used, for example, as a power or connection cable for emergency lighting, fire alarm, smoke extraction, and control and safety systems.\u003c\/p\u003e\n\n\u003cp data-end=\"567\" data-start=\"346\"\u003eThe 3G2.5 mm² cable is suitable for fixed installations that require a three-core fire-resistant cable with a protective conductor. The 90-minute fire resistance helps ensure the continued operation of critical systems for the required duration in case of fire.\u003c\/p\u003e\n\n\u003cp data-end=\"1073\" data-start=\"569\"\u003e\u003cstrong data-end=\"590\" data-start=\"569\"\u003eTechnical specifications\u003c\/strong\u003e\u003cbr data-end=\"593\" data-start=\"590\"\u003e\nEAN: 6410004203231\u003cbr data-end=\"614\" data-start=\"611\"\u003e\nManufacturer: Prysmian\u003cbr data-end=\"633\" data-start=\"630\"\u003e\nProduct code: 1250813\u003cbr data-end=\"654\" data-start=\"651\"\u003e\nSupplier product code: 20098035\u003cbr data-end=\"684\" data-start=\"681\"\u003e\nCable type: FIRETUF FRHF\u003cbr data-end=\"712\" data-start=\"709\"\u003e\nProduct type: fire-resistant cable \/ halogen-free fire-resistant cable\u003cbr data-end=\"777\" data-start=\"774\"\u003e\nCable dimension: 3G2.5 mm²\u003cbr data-end=\"802\" data-start=\"799\"\u003e\nNumber of cores: 3\u003cbr data-end=\"820\" data-start=\"817\"\u003e\nConductor cross-section: 2.5 mm²\u003cbr data-end=\"846\" data-start=\"843\"\u003e\nProtective conductor: yes\u003cbr data-end=\"864\" data-start=\"861\"\u003e\nVoltage: 500 V\u003cbr data-end=\"879\" data-start=\"876\"\u003e\nFire resistance: 90 min\u003cbr data-end=\"901\" data-start=\"898\"\u003e\nMinimum order quantity: 1 m\u003cbr data-end=\"929\" data-start=\"926\"\u003e\nPackage quantity: 1\/500\u003cbr data-end=\"952\" data-start=\"949\"\u003e\nArea of use: emergency lighting, fire alarm, smoke extraction, control and safety systems, and fixed installations\u003c\/p\u003e\n\n\u003cp data-end=\"1392\" data-start=\"1075\"\u003e\u003cstrong data-end=\"1092\" data-start=\"1075\"\u003eSuitable for, for example\u003c\/strong\u003e\u003cbr data-end=\"1095\" data-start=\"1092\"\u003e\nconnecting emergency lighting;\u003cbr data-end=\"1127\" data-start=\"1124\"\u003e\ninstalling fire alarms and safety systems;\u003cbr data-end=\"1191\" data-start=\"1188\"\u003e\nsmoke extraction and control systems;\u003cbr data-end=\"1235\" data-start=\"1232\"\u003e\nbuilding fire safety installations;\u003cbr data-end=\"1271\" data-start=\"1268\"\u003e\nfixed installations requiring fire-resistant cable;\u003cbr data-end=\"1326\" data-start=\"1323\"\u003e\nlocations requiring a 3-core 2.5 mm² fire-resistant cable.\u003c\/p\u003e\n\n\u003cp data-end=\"1530\" data-start=\"1394\"\u003eWe recommend also looking at: fire-resistant cable clips, junction boxes, fire detectors, emergency lights, wire strippers, and installation accessories.\u003c\/p\u003e\n\n\u003cp data-end=\"1637\" data-start=\"1532\"\u003eNot sure if this fire-resistant cable is suitable? Write or call us — we will help you choose the right solution.\u003c\/p\u003e\n","brand":"PRYSMIAN","offers":[{"title":"Default Title","offer_id":51706677559639,"sku":"KAAB15","price":2.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0932\/9796\/7447\/files\/9210_Kaabel-tulekindel-3G25-mm-oranz.jpg?v=1783527170"},{"product_id":"kaabel-tulekindel-4x2x0-8mm2-punane","title":"Fire-resistant signal cable 4 × 2 × Ø0.8 mm, red","description":"\u003cp data-end=\"375\" data-start=\"73\"\u003eThe fire-resistant cable is suitable for connecting fire alarm, low-voltage, control, and safety systems in places where the cable must maintain operational reliability even during a fire. It is used, for example, for connecting sensors, alarm control panels, sirens, control circuits, and other security system components.\u003c\/p\u003e\n\n\u003cp data-end=\"776\" data-start=\"377\"\u003eThe 4 × 2 × 0.8 mm cable is suitable for establishing multi-pair signal and control circuits. The red outer sheath makes the cable easier to identify in an installation, and its FE180\/E90 fire resistance makes it a suitable choice for fire safety and evacuation systems. In the VE list, the product is labeled as \u003cstrong data-end=\"737\" data-start=\"665\"\u003e“Fire-resistant cable HTKSHekw\/JE-H(ST)H FE 4x2x0.8 180\/E90 red T500”\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp data-end=\"1152\" data-start=\"778\"\u003e\u003cstrong data-end=\"799\" data-start=\"778\"\u003eTechnical specifications\u003c\/strong\u003e\u003cbr data-end=\"802\" data-start=\"799\"\u003e\nCable type: HTKSHekw\/JE-H(St)H\u003cbr data-end=\"836\" data-start=\"833\"\u003e\nProduct type: fire-resistant signal\/low-voltage cable\u003cbr data-end=\"896\" data-start=\"893\"\u003e\nCable dimensions: 4 × 2 × 0.8 mm\u003cbr data-end=\"926\" data-start=\"923\"\u003e\nNumber of pairs: 4\u003cbr data-end=\"943\" data-start=\"940\"\u003e\nNumber of wires per pair: 2\u003cbr data-end=\"968\" data-start=\"965\"\u003e\nConductor diameter: 0.8 mm\u003cbr data-end=\"992\" data-start=\"989\"\u003e\nFire resistance: FE180 \/ E90\u003cbr data-end=\"1019\" data-start=\"1016\"\u003e\nColor: red\u003cbr data-end=\"1034\" data-start=\"1031\"\u003e\nPackaging quantity: T500\u003cbr data-end=\"1056\" data-start=\"1053\"\u003e\nApplication area: fire alarms, alarm systems, low-voltage, control, and safety systems\u003c\/p\u003e\n\n\u003cp data-end=\"1424\" data-start=\"1154\"\u003e\u003cstrong data-end=\"1171\" data-start=\"1154\"\u003eSuitable for, e.g.\u003c\/strong\u003e\u003cbr data-end=\"1174\" data-start=\"1171\"\u003e\nfire alarm installations;\u003cbr data-end=\"1218\" data-start=\"1215\"\u003e\nconnecting sensors;\u003cbr data-end=\"1243\" data-start=\"1240\"\u003e\nconnecting alarm control panels and sirens;\u003cbr data-end=\"1286\" data-start=\"1283\"\u003e\ncontrol and safety systems;\u003cbr data-end=\"1322\" data-start=\"1319\"\u003e\nbuilding fire safety installations;\u003cbr data-end=\"1358\" data-start=\"1355\"\u003e\nplaces where a 4-pair fire-resistant signal cable is required.\u003c\/p\u003e\n\n\u003cp data-end=\"1571\" data-start=\"1426\"\u003eWe also recommend checking out: fireproof cable clamps, junction boxes, fire detectors, alarm control panels, sirens, wire strippers, and installation accessories.\u003c\/p\u003e\n\n\u003cp data-end=\"1677\" data-start=\"1573\"\u003eNot sure if this fire-resistant cable is the right one? Write or call us — we will help you choose the right solution.\u003c\/p\u003e\n","brand":"Elektripood.ee","offers":[{"title":"Default Title","offer_id":51706686079319,"sku":"JUHE74","price":1.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0932\/9796\/7447\/files\/9212_Kaabel-tulekindel-4x2x08-mm-punane.jpg?v=1783527160"},{"product_id":"kaabel-tulekindel-2x1-5mm2-punane","title":"Fire-resistant cable 2x1.5 mm² orange","description":"\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\n\u003cdiv data-is-intersecting=\"true\" data-turn-id-container=\"request-6a0c4dd1-8120-83eb-9443-83aae163cbd7-103\"\u003e\n\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" data-scroll-anchor=\"false\" data-testid=\"conversation-turn-590\" data-turn=\"assistant\" data-turn-id=\"request-6a0c4dd1-8120-83eb-9443-83aae163cbd7-103\" data-turn-id-container=\"request-6a0c4dd1-8120-83eb-9443-83aae163cbd7-103\" dir=\"auto\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\n\u003cdiv class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-message-author-role=\"assistant\" data-message-id=\"6014f1b0-6749-4bd6-a2e9-b0a8c5b965d5\" data-message-model-slug=\"gpt-5-5-thinking\" data-turn-start-message=\"true\" dir=\"auto\" tabindex=\"0\"\u003e\n\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\n\u003cp data-end=\"312\" data-start=\"55\"\u003eEupen's fire-resistant cable is suitable for electrical installations where it is necessary to ensure cable reliability even in fire conditions. It is used, for example, as a power or connecting cable for emergency lighting, smoke extraction, fire alarm systems, as well as control and safety systems.\u003c\/p\u003e\n\n\n\u003cp data-end=\"504\" data-start=\"314\"\u003eThe (N)HXH-O E90 2 × 1.5 mm² cable is halogen-free and designed for permanent installations. The E90 fire resistance rating helps ensure that essential systems continue to operate during a fire for the specified duration.\u003c\/p\u003e\n\n\n\u003cp data-end=\"1011\" data-start=\"506\"\u003e\u003cstrong data-end=\"527\" data-start=\"506\"\u003eTechnical specifications\u003c\/strong\u003e\u003cbr data-end=\"530\" data-start=\"527\"\u003e\nManufacturer: Eupen\u003cbr data-end=\"546\" data-start=\"543\"\u003e\nProduct code: 1250800\u003cbr data-end=\"567\" data-start=\"564\"\u003e\nSupplier product code: G37709\u003cbr data-end=\"595\" data-start=\"592\"\u003e\nCable type: (N)HXH-O E90\u003cbr data-end=\"623\" data-start=\"620\"\u003e\nProduct type: fire-resistant cable \/ halogen-free fire-resistant cable\u003cbr data-end=\"688\" data-start=\"685\"\u003e\nCable size: 2 × 1.5 mm²\u003cbr data-end=\"715\" data-start=\"712\"\u003e\nNumber of cores: 2\u003cbr data-end=\"733\" data-start=\"730\"\u003e\nConductor cross-section: 1.5 mm²\u003cbr data-end=\"759\" data-start=\"756\"\u003e\nConductor type: RE\u003cbr data-end=\"775\" data-start=\"772\"\u003e\nVoltage: 1 kV\u003cbr data-end=\"789\" data-start=\"786\"\u003e\nFire resistance rating: E90\u003cbr data-end=\"813\" data-start=\"810\"\u003e\nFeatures: halogen-free\u003cbr data-end=\"839\" data-start=\"836\"\u003e\nMinimum order quantity: 1 m\u003cbr data-end=\"867\" data-start=\"864\"\u003e\nPackage quantity: 1\/500\u003cbr data-end=\"890\" data-start=\"887\"\u003e\nApplication area: emergency lighting, fire alarm, smoke extraction, control and safety systems, and permanent installations\u003c\/p\u003e\n\n\n\u003cp data-end=\"1334\" data-start=\"1013\"\u003e\u003cstrong data-end=\"1030\" data-start=\"1013\"\u003eSuitable for, for example\u003c\/strong\u003e\u003cbr data-end=\"1033\" data-start=\"1030\"\u003e\nconnecting emergency lighting;\u003cbr data-end=\"1065\" data-start=\"1062\"\u003e\ninstalling fire alarm and safety systems;\u003cbr data-end=\"1129\" data-start=\"1126\"\u003e\nsmoke extraction and control systems;\u003cbr data-end=\"1173\" data-start=\"1170\"\u003e\nbuilding fire safety installations;\u003cbr data-end=\"1209\" data-start=\"1206\"\u003e\npermanent installations where a fire-resistant cable is required;\u003cbr data-end=\"1264\" data-start=\"1261\"\u003e\nlocations requiring a 2-core 1.5 mm² E90 fire-resistant cable.\u003c\/p\u003e\n\n\n\u003cp data-end=\"1472\" data-start=\"1336\"\u003eWe also recommend checking out: fire-resistant cable clamps, junction boxes, fire detectors, emergency lights, cable strippers, and installation accessories.\u003c\/p\u003e\n\n\n\u003cp data-end=\"1579\" data-start=\"1474\"\u003eNot sure if this fire-resistant cable is the right one? Write or call us — we will help you choose the correct solution.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n","brand":"EUPEN","offers":[{"title":"Default Title","offer_id":51706686243159,"sku":"JUHE73","price":1.16,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0932\/9796\/7447\/files\/9209_Kaabel-tulekindel-2x15-mm-oranz.jpg?v=1783527176"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0932\/9796\/7447\/collections\/b87ab139-061e-4b9c-9cf8-73ef2dd34060.png?v=1782977094","url":"https:\/\/www.elektripood.ee\/en\/collections\/tulekindlad-kaablid.oembed","provider":"Elektripood.ee","version":"1.0","type":"link"}